Regulation and Detection

Cardarine has no approved therapeutic indication and is not marketed as a medicine. The World Anti-Doping Agency lists GW501516 as a prohibited substance at all times, covering both in-competition and out-of-competition periods. National laws vary: some countries treat it as an unapproved drug subject to import controls, while others have specific restrictions on sale for human consumption. It is often sold as a research chemical, a label that does not imply safety or legality. Enforcement actions have targeted online vendors and shipments.

Anti-doping laboratories identify GW501516 and related metabolites using liquid chromatography coupled with tandem mass spectrometry. Urine is the most common matrix, though blood and dried blood spots may also be analyzed. The method targets the parent compound and phase I and phase II metabolites, which extend the detection window. Because the substance is prohibited at all times, athletes can be tested outside competition. Detection limits and windows depend on the assay, sample type, and individual metabolism.

Background and Regulatory Status

Cardarine is a common name for GW501516, a synthetic compound first described in the 1990s as a selective agonist of the peroxisome proliferator-activated receptor delta. It was studied in preclinical models for metabolic and cardiovascular conditions, but it has not been approved as a medicine in the United States, Europe, or other major jurisdictions. Retail products labeled as cardarine are generally research chemicals or supplements, not pharmaceutical formulations. Because human safety and efficacy data remain limited, regulatory agencies treat it as an unapproved substance rather than a therapeutic product.

Sporting authorities added GW501516 to prohibited lists after it appeared in athlete samples and online markets. The World Anti-Doping Agency classifies it as a hormone and metabolic modulator, and its use can lead to an anti-doping rule violation. Some early laboratory work suggested effects on fatty acid oxidation and endurance-related metabolism in animals, but those findings do not establish safe or effective use in people. Reports of adverse events in humans are scarce and often anecdotal, which complicates risk assessment.

Cardarine at a glance

PropertyValueNotes
Regulatory statusProhibited in sport; not approved as medicineListed by WADA at all times.
Common synonymsGW501516, GW-501516, endurobolCardarine is a colloquial name.
Typical analytical methodLC-MS/MSDetects parent compound and metabolites.
Common test matrixUrineBlood and dried blood spots also possible.
Legal classificationVaries by countryOften treated as unapproved drug or research chemical.

Identity and Pharmacological Classification

Cardarine is a common name for GW501516, also GW-1516, a synthetic compound developed as a peroxisome proliferator-activated receptor delta (PPARδ) agonist. It belongs to a class of agents that modulate gene transcription related to lipid and energy metabolism. The compound was studied in preclinical and early clinical research for metabolic and cardiovascular conditions, but it did not progress to approved therapeutic use. Its name appears in fitness and sports contexts despite not being approved as a drug.

PPARδ is a nuclear receptor that influences transcription of genes involved in fatty acid oxidation, lipid transport, and energy homeostasis. GW501516 binds and activates this receptor with high selectivity relative to PPARα and PPARγ in laboratory assays. Activation alters expression of target genes in skeletal muscle, liver, and adipose tissue in animal models. The exact clinical consequences of these changes in humans remain incompletely characterized, and observed effects in animals do not establish therapeutic benefit or safety.

Related pages on this site

Mechanism and Detection Methods

Detection of GW501516 in biological samples generally relies on liquid chromatography coupled with tandem mass spectrometry. Urine is a common matrix in anti-doping analysis, while blood or plasma may be used in research settings. Sample preparation can involve enzymatic hydrolysis, protein precipitation, or solid-phase extraction before instrumental analysis. Because the compound undergoes metabolism, assays may target the parent molecule, one or more metabolites, or both. Detection windows are not fixed; they depend on factors such as dose, route, individual metabolism, and assay sensitivity. Reference standards are required for accurate identification and quantification.

Handling and quality assessment of cardarine reference material follow general laboratory practices for poorly characterized compounds. It typically appears as a white to off-white powder and is sparingly soluble in water but soluble in organic solvents such as dimethyl sulfoxide and ethanol. Storage recommendations usually specify a cool, dry, dark place, with long-term storage at low temperature and desiccation. Purity may be checked by high-performance liquid chromatography with ultraviolet detection, while identity is confirmed by mass spectrometry and nuclear magnetic resonance. No pharmacopeial monograph exists, so reported purity and stability depend on the supplier’s methods.

Supporting material

A 2004 essay on the relation between car colour and safety stated that no previous studies had been scientifically conclusive. Since then, a Swedish study found that pink cars are involved in the fewest and black cars are involved in the most crashes (Land transport NZ 2005). In Auckland New Zealand, a study found that there was a significantly lower rate of serious injury in silver cars, with higher rates in brown, black, and green cars. The Vehicle Colour Study, conducted by Monash University Accident Research Centre (MUARC) and published in 2007, analysed 855,258 crashes that occurring between 1987 and 2004 in the Australian states of Victoria and Western Australia that resulted in injury or in a vehicle being towed away. The study analysed risk by light condition. It found that in daylight, black cars were 12% more likely than white to be involved in a collision, followed by grey cars at 11%, silver cars at 10%, and red and blue cars at 7%, with no other colours found to be significantly more or less risky than white. At dawn or dusk, the risk ratio for black cars jumped to 47% more likely than white, and that for silver cars to 15%. In the hours of darkness, only red and silver cars were found to be significantly more risky than white, by 10% and 8% respectively.

A safety modification to Mark 39 Mod 2 weapons known as Alt 197 had been approved in January 1960, but not yet applied to all deployed weapons prior to the Goldsboro accident, and was not applied to the weapons involved in the accident. Alt 197 replaced the MC-772 Arm/Safe switch with the MC-1288 Arm/Safe switch, with the main change being that the latter would prevent the charging of the low-voltage thermal battery when the Arm/Safe switch was in the "Safe" position, and as such would make sure that no electrical current was available anywhere within the bomb to power additional switches or hardware, legitimately or not. After the accident, all other Mark 39 Mod 2 weapons without the modification were taken off of deployment status ("red-lined") until the modification could be applied to the remaining inventory of the weapons.

The α2 receptor couples to the Gi/o protein. It is a presynaptic receptor, causing negative feedback on, for example, norepinephrine (NE). When NE is released into the synapse, it feeds back on the α2 receptor, causing less NE release from the presynaptic neuron. This decreases the effect of NE. There are also α2 receptors on the nerve terminal membrane of the post-synaptic adrenergic neuron. Actions of the α2 receptor include: decreased insulin release from the pancreas increased glucagon release from the pancreas contraction of sphincters of the GI-tract negative feedback in the neuronal synapses - presynaptic inhibition of norepinephrine release in CNS increased platelet aggregation decreases peripheral vascular resistance α2 agonists (see actions above) can be used to treat: hypertension – decrease blood pressure-raising actions of the sympathetic nervous system α2 antagonists can be used to treat: impotence – relax penile smooth muscles and ease blood flow depression – enhance mood by increasing norepinephrine secretion Subtype unspecific β agonists can be used to treat:

Sources: en.wikipedia.org

Supporting material

Automated iterative homologation enables stepwise construction of carbon chains through repeated one-carbon extensions of boronic esters. Two reactions adapted to automation are the Matteson homologation, which inserts a methylene unit via chloromethyllithium, and chiral carbenoid homologation, which uses lithiated benzoate esters. Both methods have been implemented on robotic platforms under low-temperature, inert conditions. Using these techniques, up to six consecutive C(sp³)–C(sp³) bond-forming homologations have been performed without manual intervention, representing the highest number reported in an automated synthesis. The approach has also been applied to the synthesis of intermediates of the natural product (+)-kalkitoxin.

C4H2N2O4 + GSH → C4H3N2O4• + GS• C4H3N2O4• + GSH → C4H4N2O4 + GS• C4H4N2O4 + O2 → C4H3N2O4• + O2•− + H+ C4H3N2O4• + O2 → C4H2N2O4 + O2•− + H+ Because it selectively kills the insulin-producing beta-cells found in the pancreas, alloxan is used to induce diabetes in laboratory animals. This occurs most likely because of selective uptake of the compound due to its structural similarity to glucose as well as the beta-cell's highly efficient uptake mechanism (GLUT2). In addition, alloxan has a high affinity to SH-containing cellular compounds and, as a result, reduces glutathione content. Furthermore, alloxan inhibits glucokinase, a SH-containing protein essential for insulin secretion induced by glucose. Most studies have shown that alloxan is not toxic to the human beta-cell, even in very high doses, probably because of differing glucose uptake mechanisms in humans and rodents. Alloxan is, however, toxic to the liver and the kidneys in high doses, as these are tissues where the GLUT2 transporter is expressed in humans. Streptozotocin

N-Acetylcysteine amide (abbrev. NACA, AD4 and also known as acetylcysteinamide) is an amide derivative of N-acetylcysteine (NAC) that appears to have better blood–brain barrier permeability and bioavailability possessing potential antioxidant and anti-inflammatory activity When administered, NACA increases glutathione levels. Glutathione neutralizes reactive oxygen species, reduces oxidative stress, and prevents induced cell damage and apoptosis. NACA has increased lipophilicity and membrane permeability compared to NAC. This compound belongs to a class of experimental compounds known as N-acyl-alpha-amino acids and their derivatives. These are compounds containing an alpha-amino acid (or its derivative) with an acyl group on the terminal nitrogen atom.

Sources: en.wikipedia.org

Frequently asked questions

Is cardarine legal?

Legal status varies by country. It is not approved as a medicine, and it is prohibited in sport. Some jurisdictions restrict import, sale, or possession.

How is cardarine detected in athletes?

Laboratories use liquid chromatography-tandem mass spectrometry to detect GW501516 and its metabolites. Urine is commonly tested, and testing can occur in and out of competition.

Is cardarine a SARM?

No, cardarine is not a SARM. It is a PPARδ agonist, which acts on a different receptor. The two classes are often confused in online discussions.

Is cardarine approved for human use?

No. Major drug regulators have not approved GW501516 for treating any medical condition. Products sold as cardarine are typically unapproved research chemicals or supplements, so their contents and safety are not assured.